Laboratory-scale SFE System
.
Download Catalogue
SUPEREX
F-500
Supercritical Extraction System
F-500
.Video
F-500 - Video
Features
500 ml extractor column,
Working pressure up to 345 Bar,
Working temperature up to 70 °C,
Extraction in Continuous (Dynamic) CO2 flow mode,
Temperature control with PID algorithm,
Digital fully automatic pressure control,
Optional Co-solvent (10 ml/min) pump,
Easy sample loading,
Use of synthetic fabric baskets for solid samples,
Changeable flow direction for liquid samples,
Possibility to take extract directly into Falcon tubes,
Liquid trapping feature in the secondary Falcon separator,
observable flow rate,
Independent electronic and mechanical pressure safety system,
All surfaces in contact with food are stainless steel,
Smooth-honed reactor column against microbial attachments,
SUPEREX
F-500I
Impregnation Module
Features
500 ml+250 ml extractor column,
Working pressure up to 345 Bar,
Working temperature up to 70 °C,
Continuous (Dynamic) CO2extraction in flow mode,
Temperature control with PID algorithmdead,
Digital fully automatic pressure control,
Optional Co-solvent (10 ml/min) pump,
Easy sample loading,
Use of synthetic fabric basket for solid samples,
Changeable flow direction for liquid samples,
Possibility to take extract directly into Falcon tubes,
Liquid trapping feature in the secondary Falcon separator,observable flow rate,
The material to be impregnated is loaded into the second column,
contact lenses etc. product-specific loading basket,
Independent electronic and mechanical pressure safety system,
All surfaces in contact with food are stainless steel,
Smooth-honed reactor column against microbial attachments
SUPEREX
F-500M
Micronization Module
Features
500 mL main extractor column,
250 mL impregnation column,
Basket with shelf to place the material to be impregnated in the 250 mL column,
Micronization pump and nozzle for 500 mL column,
Stainless steel basket where micronized nanoparticles are collected,
Working pressure up to 345 Bar,
Operating temperature up to 70 °C,
Continuous (Dynamic) CO2 extraction in flow mode,
Temperature control with PID algorithmdead,
Digital fully automatic pressure control,
Easy sample loading possibility,
Use of synthetic fabric baskets for solid samples,
Changeable flow direction for liquid samples
Possibility of taking extract directly into Falcon tubes,
Liquid trapping feature in the secondary Falcon separator,
Observable flow rate,
The material to be impregnated is loaded into the second column,
Contact lenses etc. Loading basket specific to products,
Flow can be provided between columns with valves,
Independently working electronic and mechanical pressure safety system,
All surfaces in contact with food are stainless steel,
Smooth-honed reactor column against microbial adhesion,
SUPEREX
SC-1000
Supercritical Extraction System
SC-1000
.Video
SC-1000 - Video
Features
Optional
1 Liter extractor column,
2 separator columns,
With CO2 liquefaction system,
Working pressure up to 345 Bar,
Working temperature up to 70 °C,
Temperature control in separators,
CO2 recycling system,
All surfaces in contact with food are stainless steel,
Smooth-honed reactor columns against microbial attachments,
Temperature control with PID algorithm,
Digital fully automatic pressure control,
Possibility to load samples with a stainless steel basket or a cloth basket,
Gas feeding or cyclone flow feature from the bottom to the separators,
Trap solution to the separators; water, alcohol etc. can be added.
CO2 recovery system,
Adding an extra extractor,
Adding an extra separator,
Pressure control in separators,
Fully automatic flow control/Automatic back-pressure regulator (BPR).
SUPEREX
SUPEREX SC-1000 SUB-CRITICAL
Subcritical Water Extraction System
Features
1 Liter extractor vessel,
2 separator vessels,
Working pressure up to 300 Bar,
Working temperature up to 200 °C,
Design suitable for sub-critical water extraction,
Temperature control and powerful cooling in separators,
All surfaces in contact with food are stainless steel,
Smooth-honed reactor columns against microbial attachments,
PID algorithm temperature control,
Digital fully automatic pressure control,
Automatic back pressure regulator (aBPR),
Sample loading with stainless steel basket or fabric basket,
Bottom gas feeding or cyclone flow feature to separators,
Supercritical carbon dioxide module can be added as an option,
Green extraction of polar groups such as phenolic compounds,
SUPEREX
TH-1000
SUPEREX ThermoHyper
TH-1000
.Video
TH-1000 - Video
Features
Special design suitable for supercritical water and carbon dioxide studies,
1 Liter extractor column,
2 separator columns,
With CO2 liquefaction system,
Working pressure up to 345 Bar,
Working temperature up to 70 °C,
Temperature control in separators,
CO2 recycling system,
All surfaces in contact with food are stainless steel,
Smooth-honed reactor columns against microbial attachments,
Temperature control with PID algorithm,
Digital fully automatic pressure control,
Possibility to load samples with a stainless steel basket or a cloth basket,
Gas feeding or cyclone flow feature from the bottom to the separators,
Trap solution to the separators; water, alcohol etc. can be added.
SUPEREX
F-1000
Counterflow Supercritical Extraction System
F-1000
.Video
F-1000 - Video
Features
1 Liter extractor column
Extra 0.5 liter extractor column,
With CO2 liquefaction system,
Working pressure up to 345 Bar,
Working temperature up to 70 °C,
All surfaces in contact with food are stainless steel,
Smooth-honed reactor columns against microbial attachments,
Special design for extraction from liquid sample,
Extra liquid feed pump,
Instant visible flow rate on the flowmeter,
Temperature control with PID algorithm,
Digital fully automatic pressure control,
Easy sample loading,
Independent electronic and mechanical pressure safety system,
SUPEREX
SC-2000
Supercritical Extraction System
Features
2 Liter extractor column,
Extra 0.5 Liter extractor column,
Working pressure up to 345 Bar,
Working temperature up to 70 °C,
With CO2 liquefaction system,
All surfaces in contact with food are stainless steel,
Smooth-honed reactor columns against microbial attachments,
Special design for aroma extraction from liquid sample,
Easy sample loading and cleaning process,
Three separators, two of which are pressure and temperature controlled,
Replaceable cyclone flow or bottom feeding apparatus in separators,
Trap solution, water, alcohol, etc. to the separators. can be added.
Digital Automatic back pressure regulator (BPR),
With CO2 recycling system
Optional CO2 recovery feature,
Temperature control with PID algorithm,
Gas feeding or cyclone flow feature from the bottom to the separators,
SUPEREX
SC-4000
Supercritical Extraction System
SC-4000
.Video
SC-4000 - Video
Features
Extraction vessel volume: 4 L
Maximum pressure: up to 345 bar
Maximum temperature: up to 90°C
Maximum CO2 flow rate: 400 ml/minute
Two 1 L separators with pressure and temperature control (up to 220 bar and up to 70°C)
CO2 liquefaction system for efficient pressure increase
Co-solvent feed pump (50 ± 1.5 ml/minute)
CO2 recycling system with 90-95% efficiency
SUPEREX
AERO-1000
Supercritical Drying System
Features
1 Liter extractor column,
Large diameter extractor column designed for airgel drying,
1 separator column,
Specially designed stainless steel baskets for loading sol-gel sample,
Working pressure up to 138 Bar,
Working temperature up to 70 °C,
Liquefaction unit for stable CO2 supply,
The separator column, where the alcohol placed with the sol-gel can be recovered,
Temperature control with PID algorithm,
Digital fully automatic pressure control,
observable flow rate,
Adjustable CO2 supply and discharge feature at low speeds,
Adjustable pressure rise-drop curve,
SUPEREX
AERO-5000
Supercritical Drying System
Features
1 Liter extractor column,
2 separator columns,
With CO2 liquefaction system,
Working pressure up to 345 Bar,
Working temperature up to 70 °C,
Temperature control in separators,
CO2 recycling system,
All surfaces in contact with food are stainless steel,
Smooth-honed reactor columns against microbial attachments,
Temperature control with PID algorithm,
Digital fully automatic pressure control,
Possibility to load samples with a stainless steel basket or a cloth basket,
Gas feeding or cyclone flow feature from the bottom to the separators,
Trap solution to the separators; water, alcohol etc. can be added.